环氧地坪漆濕膜厚度的檢驗標準

文章时间:2018-11-10 01:38:17   浏览次数:1198

施工質量管理中,膜厚管理是一個更為重要的內容。所謂膜厚管理,是指在环氧地坪漆施工過程中控制膜厚,並在施工後對膜厚進行檢測、鑒別、質量反饋和處理的過程。薄膜厚度管理的目的是使环氧地坪塗層的厚度不僅滿足設計要求的厚度,而且避免因額外厚度造成的浪費。測量环氧地坪漆的幹膜厚度的重要性在於確保塗層達到指定的厚度,避免塗層因厚度不當而過早失效,特別是對於地板塗層。幹膜厚度的測量必須在幹膜完全幹透後用幹膜厚度測量儀進行。
In the construction quality management, the film thickness management is a more important content. The so-called film thickness management refers to the process of controlling film thickness during the construction of epoxy floor paint, and testing, identification, quality feedback and treatment of film thickness after construction. The purpose of film thickness management is to make the thickness of epoxy floor coating not only meet the design requirements, but also avoid waste caused by extra thickness. The importance of measuring the dry film thickness of epoxy floor paint lies in ensuring that the coating reaches the specified thickness and avoiding premature failure of the coating due to improper thickness, especially for floor coating. The measurement of dry film thickness must be done with a dry film thickness gauge after the dry membrane is completely dried.
地板塗料對管理的每一項都有明確的要求。例如,在塗層設計過程中,對厚膜和幹膜厚度有嚴格的規定,應按要求進行。膜厚度管理包括濕膜厚度測量和幹膜厚度檢測。在塗裝過程中,每次塗裝完成後,通常會檢測到濕膜厚度。濰坊环氧地坪漆的施工過程中可以檢測幹膜厚度,但施工後必須對幹膜厚度進行檢測。
Floor coatings have specific requirements for every透水地坪 item of management. For example, in the process of coating design, there are strict regulations印花地坪 on the thickness of thick film and dry film, which should be carried out according to the requirements. Film thickness management includes wet film thickness measurement and dry film thickness measurement. In the process of coating, wet film thickness is usually detected after finishing. Dry film thickness can be measured during the construction of Weifang epoxy floor paint, but it must be tested after construction.
很難修復的破壞性試驗實踐,所以濕膜的厚度的測量,積累每一塗層的厚度和塗料的用量的控制(如建設的不溶解的自動安平地板塗料)可以用來取代總幹膜厚度的測量。
It is difficult to repair the destructive test practice, so the measurement of wet film thickness, the control of accumulating the thickness of each coating and the amount of paint (such as the construction of insoluble automatic flat floor coating) can be used to replace the measurement of total dry film thickness.