廠傢介紹老化房系統及安全措施保護
老化房系統及安全措施保護1、老化過程可全自動控制,具有部分異常自處理功能,讓操作自動化、簡單化。a.動切斷循环風機、電熱等電源;老化房自行降溫,繼續老化,待總老化時間到,黃色燈亮起,告知老化完畢。b.產品超溫保護控制。在溫度超過產品老化溫度上限時,自動切斷產品供電,以保護老化房產品過溫老化,影響其性能;同時蜂鳴器響、紅色燈亮起。溫度正常自動恢復供電。c.加熱器PID控制。采用SSR配套使用,溫度到達設定溫後,根據需要自動無級調節加熱器功率大小,器件無機械損耗且室內溫度穩定性高。
Aging room system and safety measures protection 1. Aging process can be fully automatic control, with part of the abno透水地坪rmal self-handling function, so that the operation is automated and simplified. A. Turn off the power supply of circulating fan and electric heating; the aging room cools itself and keeps aging. When the total aging time is up, the yellow light will be on and the aging will be notified. B. Overtemperature protection control of products. When the temperature exceeds the upper limit of the product aging temperature, the power supply of the product is automatically cut off to protect the aging property from overheating and aging, affecting its performance; at the same time, the buzzer sounds and the red light turns on. Normal temperature automatically restores power supply. C. PID control of heater. SSR is used together. When the temperature reaches the set temperature, the power of the heater can be adjusted automatically and steplessly according to the need. The device has no mechanical loss and high indoor temperature stability. 2、控制系統集成老化功能設計。設計功能控制電櫃,老化所需時間、溫度、各類操作開關可在一個控制電櫃上操作;電櫃面板設計美觀、操作簡單。
2. Integrated aging function design of control system. Designing functional control cabinet, aging time, temperature, all kinds of operating switches can be operated on a control cabinet; cabinet panel design beautiful, simple operation.
3、具有多重保護功能,安全可靠。
3. It has multiple protection functions and is safe and reliable.
a、加熱器防MC粘連設計。SSR無觸點關斷,無機械動作、損耗,杜絕意外。
A. Anti-MC adhesion design of heater. SSR has no contact turn-off, no mechanical action and loss, to prevent accidents.
b、加熱器連接采用耐高溫線材。
B. The heater is connected by high temperature resistant wire.
c、室內安裝防爆型照明燈,提高燈泡壽命,防止外力撞破。
C. Install explosion-proof lighting in the room to prolong lamp life and prevent external force from breaking.
d、庫體采用難燃保溫材料,保溫性能好,安全系數高。
D. The reservoir body is m环氧地坪ade of non-flammable heat preservation material, which has good heat preservation performance and high safety factor.
e、超溫聲光報示功能:老化過程中出現超溫狀況,則亮紅燈,蜂鳴器響起。
E. Overtemperature acoustooptic function: If overtemperature occurs during aging, the red light will be turned on and the buzzer will ring.
f、電熱防幹燒,風機故障或風管內溫度過高時自動切斷整個電源,同時蜂鳴器響。
F. Electric heating and dry burning prevention. When the fan fails or the temperature in the duct is too high, the whole power supply will be cut off automatically, and the buzzer will ring at the same time.
g、電加熱與風機聯動設計,風機未能啟動時加熱器無法單獨啟動。
G. Electric heating and fan linkage design, the heater can not start alone when the fan fails to start.
辛苦整理!轉載請註明來自http://www.chinasavant.cn/show.asp?id=113